EasyManua.ls Logo

GRAPHTEC FC9000-140 - Error Messages in GP-GL Command Mode

GRAPHTEC FC9000-140
402 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16-6
Error Messages in GP-GL Command Mode
Error
Displayed
LCD Display Cause Solution
E02001 7KHSORWWHUUHFHLYHGDQXQUHFRJQL]DEOH
command.
Press the [ENTER] key.
Noise came in when the computer was
turned on.
&RQÀJXUHWRGULYHWKHSORWWHUIURPWKHPHQX
of the software.
7KHVRIWZDUHFRQÀJXUDWLRQUHJDUGLQJWKH
output device has been changed.
Reset the interface settings of the software.
The plotter's interface conditions have
changed.
Reset the interface settings of the plotter.
E02004
A command was received containing
numeric parameters that exceed that
command's permissible range.
&RQÀJXUHWRGULYHWKHSORWWHUIURPWKHPHQX
of the software.
7KHVRIWZDUHFRQÀJXUDWLRQUHJDUGLQJWKH
output device has been changed.
Reset the interface settings of the software.
The plotter's interface conditions have
changed.
Reset the interface settings of the plotter.
E02005
An error occurred in the receipt of data
within the interface.
&RQÀJXUHWRGULYHWKHSORWWHUIURPWKHPHQX
of the software.
7KHVRIWZDUHFRQÀJXUDWLRQUHJDUGLQJWKH
output device has been changed.
Reset the interface settings of the software.
The plotter's interface conditions have
changed.
Reset the interface settings of the plotter.
E02006
The data out of cutting range has been
received.
Check the data.
&KHFNWKHVL]HRIPHGLDDQGWKHFXWWLQJ
range.
&KHFNWKHPDJQLÀFDWLRQVHWWLQJ
&KHFNWKHVWHSVL]HVHWWLQJV

Table of Contents

Other manuals for GRAPHTEC FC9000-140

Related product manuals