2-37
Setting the force
Set the cutting force that is used in each of the condition numbers.
Setting range : 1 to 48
Operation
1
Press the [COND/TEST] key in the default screen.
CONDITION setting screen (1/3) is displayed.
Supplement
It will return to CONDITION setting screen (1/3)
without changing the settings when you press
the [ESC] key (CANCEL).
2
Press the [4] key (FORCE).
FORCE setting screen is displayed.
* Display may vary depending on the selected condition number.
3
Press the POSITION (
) keys and select the condition
number (CONDITION No.).
Supplement
You can set the range between 1 and 48.
4
Press the POSITION ( ) keys and increase or decrease the
setting value.
5
&RQÀUPWKHVHWWLQJDQGSUHVVWKH>(17(5@NH\6(7
6HWWLQJZLOOEHFRQÀUPHGDQGLWZLOOUHWXUQWR&21',7,21VHWWLQJVFUHHQ
(1/3).
6
Press the [COND/TEST] key.
It will return to default screen.