Model 574 Programmable Counting System (PCS)
108 - GSE Scale Systems
(P700 - P711) all "even" numbered parameters.
To conserve memory space, the indicator allows the size
of the "data" field portion of the ID to be selected. The
data field can be any value from 0 - 49 characters. Make
sure the maximum number of characters is selected with
respect to the maximum number of characters to be
entered by the operator. This will depend on the
application. If unsure of ID size, make an exaggerated
selection. Average ID sizes are between 8 - 12
characters. The indicator is factory defaulted to 12
characters. If an ID size is set to "0", it will be disabled.
The "name" portion of the ID will not appear for this ID.
All selections must be keyed in. ie.
<15> <ENTER>.
P700
Selects size for ID #1
P702
Selects size for ID #2
P704
Selects size for ID #3
P706
Selects size for ID #4
P708
Selects size for ID #5
P710
Selects size for ID #6
Naming ID's
(P700 - P711) all "odd" numbered parameters.
The second part of the ID is the "name" field. An ID
name can be up to 49 characters in length. Naming an ID
is performed in the same manner as naming Vars and
Regs. When alphabetic and other non-numeric
characters are being entered into the indicator, The
<UNITS> <PRINT> <ID> and <TARE> keys assume
the functions of arrow keys similar to those found on a
computer keyboard (see Figure 20 Keypad Cursor Keys).
The <UNITS> key serves as an up arrow to scroll
forward through the list of characters. The <PRINT>
key is used as a down arrow key to scroll backward
through the list of characters. The <ID> key can be used
as a left arrow key for backspacing. The <TARE> key
is used as a right arrow key to advance to the next
location.
When you encounter a parameter that accepts this type of
information, press <UNITS> and the indicator will place
an "A" in the ten character dot matrix portion of the
display. The <UNITS> and the <PRINT> keys together
are then used to cycle through the possible selections of
upper-case and lower-case letters, numerics and the
standard set of punctuation symbols. The selection set
starts with the letter "A". Holding down the <UNITS>
or <PRINT> keys will cycle through the selections more
quickly. When the desired character is displayed, press
<TARE> to move to the next location where an "A" will
be displayed for the start of the next character selection.
After the complete information is selected press
<ENTER>.
This operation is in effect when entering ID "data" and
while in Setup Modes P157, P158, P600 - P689, P691 -
P694, P701 - P711, P800 - P815, P850 - P865 and
P1000 - P4000. Refer to Figure 21, Character Listing
for available characters and their order of appearance.
P701
Selects name for ID #1
P703
Selects name for ID #2
P705
Selects name for ID #3
P707
Selects name for ID #4
P709
Selects name for ID #5
P711
Selects name for ID #6
14.17 View an ID
To access the first ID parameter while in the Weigh
Mode, press <ID>. The numeric display will read "id X"
where "X" is the number of the first enabled ID. The
upper line of the dot matrix display will show the first
five characters of the ID name and the lower line will
show the first five characters of the ID value. To access
any other enabled ID, either press <X> <SELECT>
where "X" is the number of the ID, or press <SELECT>
repeatedly. Press <SELECT> at the last enabled ID to
exit the ID Mode. You may press <ID> at any time to
exit the ID Mode.