GSE Scale Systems - 19
Chapter 4 Parameter Setup (Advanced) Technical Reference Manual
P600 to P637 are set aside for custom naming
parameters 0 thru 37.
P650 to P654 set up the Naming Parameters for database
recalled time and the 4 alarms.
P680 to P689 are for naming the 10 variables (VARS).
P691 to P694 are for naming the 4 registers (REGS).
P700 to P725 are for setting up the six possible ID
parameters in addition to enabling Truck In-Out
Weighing.
P731 to P746 are for setting up database parameters.
They are available if Parameter P720 has been set to
database or menu. They are used to define databases 1
thru 16. Note that the database module must be installed
in order for these parameters to appear.
P800 to P816 are for Macro Setup.
P850 to P866 name Macros 0 thru 16.
P870 to P886 selects whether a macro is allowed to be
invoked once or multiple times. Macro 0 thru 16 can be
set individually.
P900 to P982 are for the Input Interpreter setup.
P1000, P2000, P3000 and P4000 are for the 1st through
4th Custom Transmits, and define the data to be
transmitted.
P5100 to P8261 are for setting up the 32 Setpoints
relating to outputs or internal use. There are 3 choices for
each setpoint which include disable, output or input.
Diagnostic and Database use. ** Note that the model
574 can utilize the setpoints for internal software use
only. Refer to GSE for alternative setpoint output
capabilities. **
4.5 Character Entry
When alphabetic and other non-numeric characters are
being entered into the 574, the <UP ARROW>
<DOWN ARROW> <LEFT ARROW> and
<RIGHTARROW> keys assume the functions of arrow
keys similar to those found on a computer keyboard (see
Figure 8 Keypad Cursor Keys) at the end of chapter.
The <UP ARROW> key scrolls forward through the list
of characters; <DOWN ARROW> key scrolls backward
through a list of characters; <LEFTARROW> can be
used as a backspace key; <RIGHTARROW> key
advances to the next location.
When you encounter a parameter that accepts this type of
information, press <UP ARROW> key and the 574 will
place an "A" in the dot matrix portion of the display. The
<UP> and <DOWN> arrow keys are then used to cycle
through the possible selections of upper-case and lower-
case letters, numerics and the standard set of punctuation
symbols, starting with the letter A. Holding down <UP>
or <DOWN> arrow keys will cycle you through more
quickly. When the desired character is displayed, press
<RIGHT> arrow key to move to the next location where
an "A" will be displayed so you can select the next
character. This operation is in effect when entering ID
data and while in Setup Modes P157, P600-P694, P157-
P158, P701 - P711, P800 - P816, P850 - P865 and
P1000 - P4000. Refer to Figure 9 Character Listing for
the available characters and their order of appearance at
the end of this chapter.
4.6 Parameter Listing (P101 - P65010)
This section contains a listing of all of the setup
parameters contained within the 574 Counting/Weigh
System. Refer to table 3, Parameter Listing (Software
Map). We have attempted to list all of the parameters,
however, in some cases where the number of available
selections is repetitive, reasonably obvious, (as in the
case of parameter P300 series: Operational Modes)are
too numerous to list individually, an example and a
range has been substituted for the unlisted parameters.
In the case of Parameter P5100 series: Setpoints, we
have listed the full complement for only the first of the
32 existing setpoints.
Some parameters in this list may not appear, based upon
which parameters you have previously selected or
whether a particular option has been installed.
SECTION - 4.6