GSE Scale Systems - 183
Chapter 17 Truck Weighing Technical Reference Manual
5. When motion ceases, the unit compares the
incoming weight to the outgoing weight and
copies the higher of the two weights to the
Truck Gross Weight register (parameter #12),
the lower weight to the Truck Tare Weight
register (parameter #13), and the difference to
the Truck Net Weight register (parameter #14).
The In-Weight and the Truck ID are then
deleted from memory.
6. Then the Custom Transmit(s) specified by
P723 are sent.
17.6 SMALL, BIG # OR ID #6
OPERATION
Incoming Truck (full or empty):
1. Truck drives onto scale.
2. Operator presses <ID>.
3. The unit prompts: Keyin ID #.
4. Operator keys in number of truck and presses
<ENTER>.
5. When motion ceases, the instrument searches
memory to see if the entered ID is already
stored away. Since this is an In Weight, the ID
should not be found and the unit prompts
WEIGH IN and stores the In Weight along
with the ID. The specified (parameter P722)
transmissions (if any) then take place.
17.7 STORING A KEYED IN TARE
WEIGHT:
1. Operator presses <ID>.
2. The unit prompts: Keyin ID #.
3. Operator keys in the Tare Weight to be stored,
then <TARE>.
4. The unit prompts: Save Tare? ...Keyin ID#.
5. Operator keys in number of truck and presses
<ENTER>.
6. The unit prompts Tare Saved. Then the unit
stores the entered tare along with the entered
truck ID. If the truck ID was previously in
memory, then the new Tare Weight over-writes
the old data. Then the specified (parameter
P724) transmission(s) (if any) take place.
Storing An Auto Tare Weight:
1. Empty truck is driven onto scale.
2. Operator presses <ID>.
3. The unit prompts: Keyin ID#.
4. Operator presses <TARE>.
5. The unit prompts: Save Tare? ... Keyin ID#.
6. Operator keys in number of truck and presses
<ENTER>.
7. The unit prompts Tare Saved. Then the unit
stores the weight of the truck as Tare Weight
along with the entered truck ID. If the truck ID
was previously in memory, then the new Tare
Weight over-writes the old data. Then the
specified (parameter P724) transmission(s) (if
any) take place.
Outgoing Truck (full or empty):
1. Truck drives onto scale.
2. Operator presses <ID>.
3. The unit prompts: Keyin ID #.
4. Operator keys in the number of the truck and
presses <ENTER>.
5. When motion ceases, the unit searches
memory to see if the entered ID is in fact stored
away. Since this is an out-weight, the ID
should be found and the unit prompts WEIGH
OUT and recalls the In Weight. The unit then
compares the incoming weight to the outgoing
weight and stores the higher of the two weights
as the Truck Gross Weight (parameter 12), the
lower as the Truck Tare Weight (parameter 14)
and the difference as the Truck Net Weight
(parameter 13). Then the specified (parameter
P722) transmissions (if any) take place. The In
Weight along with the truck ID is then deleted
om memory.
If the recalled weight is a stored Tare Weight,
SECTION - 17.7