COMMUNICATION INTERFACE
139
Interface Configuration
USB Remote Interface
USB
configuration
PC side
connector
Type A, host
PSW side
connector
Rear panel Type B, slave
Speed
1.1/2.0 (full speed/high speed)
USB Class
CDC (communications device
class)
Steps
1. Connect the USB cable to the rear
panel USB B port.
2. Change the Rear panel-USB (F-22)
setting to USB-CDC (2).
Page 112
Configure GPIB Interface
To use GPIB, the optional GPIB to USB (GUG-001) adapter must be
used. Only one GPIB address can be used at a time.
Configure GPIB
1. Ensure the PSW is off before proceeding.
2. Connect the USB cable from the rear panel
USB B port on the PSW to the USB A port on
the GPIB to USB adapter.
3. Connect a GPIB cable from a GPIB controller to
the GPIB port on the adapter.