EasyManuals Logo

GW Instek PSW Series User Manual

GW Instek PSW Series
184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #183 background imageLoading...
Page #183 background image
INDEX
183
INDEX
Accessories ................................. 12
Alarm
description ..................................... 29
Analog connector
pin assignment ............................ 117
Analog control
output control ............................. 128
overview ...................................... 116
remote monitoring ..................... 133
resistance control current
output ...................................... 126
resistance control voltage
output ...................................... 124
shutdown control ....................... 131
status monitoring ....................... 135
voltage control current output122
voltage control voltage output119
Bleeder control
Description .................................... 27
Build date
view ................................................ 54
Caution symbol ............................ 5
CC and CV mode
description ..................................... 25
CC mode
operation ........................................ 63
Cleaning the instrument ............. 7
Configuration
calibration settings. .................... 111
LAN settings ............................... 107
Normal function settings .......... 102
normal function settings
operation ................................. 112
overview ........................................ 97
power on configuration operation114
power on configuration settings.110
script test settings ......................... 88
System settings ........................... 108
table ................................................ 97
test function settings .................... 89
USB/GPIB settings ..................... 106
Connector plug manufacturer20, 46
Conventions ................................ 51
CV mode
operation ........................................ 60
DECA SwitchLab ................. 20, 46
Declaration of conformity ....... 182
Default settings ........................ 158
reset ................................................. 53
Dimensions
diagram ........................................ 177
Display format .......................... 161
Display mode
operation ........................................ 66
Disposal instructions ................... 7
EN61010
measurement category .................. 6
pollution degree ............................. 7
Environment
safety instruction ............................ 7
Error messages ......................... 161
Ethernet
interface ........................................ 141
sockets .......................................... 142
web server ................................... 141
FAQ ............................................ 156
Filter installation ........................ 39
Front panel diagram .................. 15
Ground
symbol .............................................. 5
Grounding................................... 33
Internal resistance
description ..................................... 28
LCD conversion ........................ 161
Line voltage
PSW 30-108/80-40.5/160-21.6 .... 37
List of features ............................ 11

Table of Contents

Other manuals for GW Instek PSW Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek PSW Series and is the answer not in the manual?

GW Instek PSW Series Specifications

General IconGeneral
Ripple & Noise (CC)≤ 3mArms
ProtectionsOVP, OCP, OTP
Remote SenseYes
ProgrammableYes
Operating Temperature0°C to 40°C
Storage Temperature-20°C to 70°C
Voltage Resolution1mV
Current Resolution1mA
Current Accuracy±0.1% + 10mA
Ripple & Noise (CV)≤1mVrms
Load Regulation (CC)≤0.1% + 5mA
Line Regulation (CC)≤0.1% + 5mA
Remote InterfaceUSB, RS232