OPERATION
53
Reset to Factory Default Settings
Background
The F-88 configuration setting allows the PSW
to be reset back to the factory default settings.
See page 158 for the default factory settings.
Steps
1. Press the Function key. The
Function key will light up.
Function
2. The display should show F-
01 on the top and the
configuration setting for
F-01 on the bottom.
3. Rotate the Voltage knob to change
the F setting to F-88 (Factory Set
Value).
Voltage
4. Use the Current knob to set the
F-88 setting to 1 (Return to factory
settings).
Current
5. Press the Voltage knob to confirm.
ConF will be displayed when
successful.
Voltage
6. Press the Function key again to
exit. The function key light will
turn off.
Function

Table of Contents

Other manuals for GW Instek PSW Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek PSW Series and is the answer not in the manual?

GW Instek PSW Series Specifications

General IconGeneral
Ripple & Noise (CC)≤ 3mArms
ProtectionsOVP, OCP, OTP
Remote SenseYes
ProgrammableYes
Operating Temperature0°C to 40°C
Storage Temperature-20°C to 70°C
Voltage Resolution1mV
Current Resolution1mA
Current Accuracy±0.1% + 10mA
Ripple & Noise (CV)≤1mVrms
Load Regulation (CC)≤0.1% + 5mA
Line Regulation (CC)≤0.1% + 5mA
Remote InterfaceUSB, RS232
DisplayLCD

Related product manuals