APPENDIX
PSW Default Settings
The following default settings are the factory configuration settings
for the power supply (Function settings/Test settings).
For details on how to return to the factory default settings, see page
53.
Initial Settings
Default Setting
Output
Off
LOCK
0 (Disabled)
Voltage
0V
Current
0A
OVP
Maximum
OCP
Maximum
Normal Function
Settings
Setting
Default Setting
Output ON delay time
F-01
0.00s
Output OFF delay time
F-02
0.00s
V-I mode slew rate select
F-03
0 = CV high speed priority
Rising voltage slew rate
F-04
60.00V/s (PSW 30-XX)
160.0V/s (PSW 80-XX)
320.0V/s (PSW 160-XX)
500.0V/s (PSW 250-XX)
1600V/s (PSW 800-XX)
Falling voltage slew rate
F-05
60.00V/s (PSW 30-XX)
160.0V/s (PSW 80-XX)
320.0V/s (PSW 160-XX)
500.0V/s (PSW 250-XX)
1600V/s (PSW 800-XX)

Table of Contents

Other manuals for GW Instek PSW Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek PSW Series and is the answer not in the manual?

GW Instek PSW Series Specifications

General IconGeneral
Ripple & Noise (CC)≤ 3mArms
ProtectionsOVP, OCP, OTP
Remote SenseYes
ProgrammableYes
Operating Temperature0°C to 40°C
Storage Temperature-20°C to 70°C
Voltage Resolution1mV
Current Resolution1mA
Current Accuracy±0.1% + 10mA
Ripple & Noise (CV)≤1mVrms
Load Regulation (CC)≤0.1% + 5mA
Line Regulation (CC)≤0.1% + 5mA
Remote InterfaceUSB, RS232