23
effective output is actually limited to the power
limit of the unit. In this case the output current
and voltage then depend purely on the load
value.
Below is a comparison of the operating areas of
each power supply.
PSW 800V Series Operating Area
0
5
10
15
20
25
30
020406080100
Volt
Cur
Po
0
100
800
Current (A)
Voltage (V)
200
300
400
700
0
1
2
3
4
900
5
Type III
Type II
Type I
500
600
0.45 0.9 1.35
800
250
2.88 4.321.44
PSW 250V Series Operating Area
0
5
10
15
20
25
30
020406080100
Volt
Cur
Po
Current (A)
Voltage (V)
0
3
6
9
12
15
Type III
Type II
Type I
1.44 2.88 4.32
250
80
9 13.54.5
250
200
150
100
50
0

Table of Contents

Other manuals for GW Instek PSW Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek PSW Series and is the answer not in the manual?

GW Instek PSW Series Specifications

General IconGeneral
Ripple & Noise (CC)≤ 3mArms
ProtectionsOVP, OCP, OTP
Remote SenseYes
ProgrammableYes
Operating Temperature0°C to 40°C
Storage Temperature-20°C to 70°C
Voltage Resolution1mV
Current Resolution1mA
Current Accuracy±0.1% + 10mA
Ripple & Noise (CV)≤1mVrms
Load Regulation (CC)≤0.1% + 5mA
Line Regulation (CC)≤0.1% + 5mA
Remote InterfaceUSB, RS232
DisplayLCD