129
7000056136-0
EN
5.10.3 - Closing the gas inlet
The gas stopcock on the cylinder must be closed during journeys.
The gas stopcock (3) is installed in the cupboard under the stove.
To close the gas stove gas inlet:
■ Turn the gas stopcock (3) anticlockwise.
To close the gas cylinder supply:
■ Open the gas cylinder access door (1).
■ Turn the gas stopcock (2) clockwise.
6 - Troubleshooting
6.1 - Electrical power supply
Fault Cause Action / Solution
The interior lighting
does not function.
No 12-V power supply
on the control panel.
Check that the control panel is
switched on.
Defective LED panel. Replace the LED panel with an
equivalent device (same type,
size, and power rating).
The 20-A "Interior
LED lighting" fuse is
defective.
Replace the fuse.
No 230-V power
supply, despite the
connection to the
230-V mains system.
The 230-V circuit
breaker has tripped.
Reset the 230-V circuit breaker.
The earth leakage
switch and/or circuit
breakers have tripped.
Reset the earth leakage switch
and/or circuit breakers.
The earth leakage
switch or the circuit
breakers do not
remain switched on.
Contact your dealer to check
the 230 V installation.
The 12-V power
supply does not
function, despite the
connection to the
230-V mains system.
The 230-V circuit
breaker has tripped.
Reset the 230-V circuit breaker.
The 20-A "Refrigerator
and USB sockets" fuse
is defective.
Replace the fuse.
The cabin battery
does not charge
when the vehicle
is connected to the
230-V mains system.
The built-in charger is
defective.
Contact HANROAD Customer
Service.