7-2
HN4000 Hardware Installation Guide 920550-5020 Rev 14
RefertoAppendixEforinformationaboutcontactingTechnicalSupport(viaemailortele‐
phone)oraccessingtheTechnicalSupportWeb‐basedCustomerPortal.
........
Oneormoreofthenumbered2BASE‐TL
LEDsareoff.
Innormaloperation,anumbered2BASE‐TLLEDwillbeoffifthereisno
copperpairconnectedtotheport(orifacopperpairisconnectedattheport
butisnotterminatedatanoperationalremotedevice).
Ifanumbered2BASE‐TLLEDisoffwhenacopperpairisconnected:
1.Verifythatthecopperpairsareterminatedatanoperationalremotedevice.
2.Verifythatthecopperpairsarewiredcorrectlyinthecopper‐pairCAT 5
cable.Referto”Cabling2BASE‐TLPorts” on page 4‐7forwiring
information.
ANetworkLINKLEDisoff. Innormaloperation,theNetworkLINKLEDisonwhenalinkisdetected
betweentheHN4000andaremotedevice.
1.Verifythatacableisconnectedproperlytotheportonanoperational
Ethernetdevice.
ANetworkACTLEDisoff. Innormaloperation,theNetworkACTLEDblinkswhenthedevicedetects
trafficontheNetworkport.
IftheNetworkACTLEDisoffandtheNetworkLINKLEDison:
1.VerifythatthereisEthernettrafficonthenetworkconnection.
TheCoolingUnitFAILLEDison. IftheCoolingUnitFAILLED
ison,itisanindicationthatoneormoreofthe
fansintheCoolingUnithavefailed.Toavoiddamagetotheequipment,the
CoolingUnitshouldbereplacedasdescribedin”CoolingUnitModule
Replacement” on page 6‐5.
TheFAILLEDwillalsobeonwhennoCoolingUnit
isinstalled.
YoucanverifythattheHN4000LEDsareworkingproperlybypressingandholdingtheLAMPTESTbutton
forabout2seconds.AllLEDsonthefrontpanelshouldturnonuntilyoureleasethebutton.
Table 7-1 HN4000 Troubleshooting Steps (Continued)
Condition Solution