17
Acc. sensor No. 1
Possible settings: ”1“ / “2“ / “3“ / “4“ .
This setting is important if the sensor is required for other Logotherm control devices.
BSB-F5(1-4) NO
Possible settings: YES“ / “NO“ / “BUS“.
YES: If the sensor is installed at the Lambda-Control 1
plus
.
BUS: If the temperature of the sensor is requested over the CAN-bus.
Acc. volume 1 0.0m
3
Setting range: 0.0m
3
99.9m
3
This position requires installed BSB.
The volume must be set no addition for water content in the heating circuits, the controller
learns constantly about the energy demand from the water contents of the heating circuits and
considers them through the BSB.
In case of a hot water zone in the accumulator, that cannot be sensed by F4, this volume above F4
(hot water zone) must not be set as accumulator volume. The controller learns constantly about
the energy demand from the water contents of the heating circuits and considers them through
the BSB.
The data of the accumulator manufacturer does not always coincide with the actual data of the
volume, or the volume may be used completely by the hydraulic connection positioning. The
controller learns constantly about the energy demand from the water contents of the heating
circuits and considers them through the BSB.
Runtime Y1 150sec Setting range: 90sec 240sec
Return valve Y1 Actuator motor runtime in seconds.
Check for correct setting, fewer control motions are required.
Y1 Rotary valve
Type of return valve Y1.
Possible settings: “Rotary valve” / “Plunger-Plate” / “Ball valve”.
Check for proper adjustment; thus, fewer control motions are required.
Runtime Y2 150sec Setting range: 90sec 240sec
Note: Only with installed Y2 Actuator motor runtime in seconds.
Check for proper adjustment; thus, fewer control motions are required.
Bus No. 1 Setting range: 1-15
Numbering of the controller if several Lambda-Control 1
plus
- controllers are on the bus.
Be mindful that the set Bus No. was only allocated once per Lambda-Control 1
plus
.
Note 26.33 NO
Note: Fuel is too large or too wet.
Possible settings: YES“ / “NO.
YES: The note is displayed. The user should chop the fuel into smaller pieces and/or dry them better.
Note 26.34 NO
Note: Fuel is too small or too dry.
Possible settings: YES“ / “NO.
YES: The note is displayed. The user may burn the smaller fuel mixed with larger ones.
Pellet/Oil/Gas NO
Possible settings: Oil-Gas“ / “Pellet“ / “NO
Oil-Gas: If an Oil/Gas boiler is installed.
Pellet: If a Pellet boiler is installed.
This menu item is only displayed if systems have a Pellet or Oil/Gas boiler.
Ext.-1 HC NO
Possible settings: YES“ / “NO
YES: If a heating circuit-extension module is installed (see user manual “Extension module-1 Heating
circuit”).
Ext.-Ignition NO
Possible settings: YES“ / “NO“
YES: If an ignition-extension module is installed (see user manual “Extension module-Ignition”).
Surveillance NO
Possible settings: YES“ / “NO“
YES: If a boiler surveillance device for starting a fire is installed (vacuum unit, door switch…).