9.01 Acc. volume 1 0.0m³ Setting range: 0.0m
3
– 99.9m
3
Only displayed if BSB – sensor F5(1-4) and F4 are installed.
Please read notes in chapter 2.4.
9.02 Acc. reserve 10% Setting range: 0% – 50%
Only displayed if BSB – sensor F5(1-4) and F4 are installed.
Reserve in storage capacity to be kept for use of residual heat – solar system – heating application
(see chapter 1.10 and 5).
9.03 Refuel signal 40°C Setting range: 20°C – 80°C
Only displayed if the sensor F4 is installed (see chapter 1.17).
9.04 SLA ON < 60°C Setting range: 20°C – 70°C
Only displayed if the sensor F4 is installed (see chapter 1.8).
9.05 RSA ON < 50°C Setting range: 0°C – 90°C
Only displayed if the sensor F4 is installed (see chapter 1.7).
9.06 PAE ON < 50°C Setting range: 20°C – 70°C
Only displayed if the sensor F4 is installed (see chapter 1.9).
6 Date and Time
Note:
● If date and time are not set, BSB is carried out without heating demand.
● Date and time must be set when leaving the menu, if the settings are applied
the error 26.24 Date – Time not set is deleted.
● During a power cut-off <5h the setting is maintained (power reserve of approx. 5h.
The summer/winter setting must be changed manually, if there is no DCF77-Receiver.
● If there is a DCF77-Receiver installed, the Date-Time and summer/winter settings are adjusted
automatically.