Acc. t.-F4 °C
The accumulator temperature at sensor F4.
BSB-temp.-F5 °C
Only in conjunction with the BSB option.
Averaged accumulator temperature of the sensors F5(1-4).
Acc. load kWh
Only in conjunction with the BSB option.
Current accumulator load in kWh.
Note: If the accumulator temperature is lower than the value set in 9.03 Refuel signal, a negative value
may be displayed (see chapter 1.20).
middle PH kW
Only in conjunction with the BSB option.
This position is only present with installed BSB — sensor F5 (1-4) and F1.
This value shows the averaged heating demand of the last 24h – derived from the settings in 5.07 TA-design and 5.08
PH-design.
HC release %
Only in conjunction with a Multi-Control 2
plus
or an extension-module – 1HC.
The release of the heating circuits (see PAE function in chapter 1.9).
If the HC release value is set at 50%, the heating demand of the heating circuits is limited to 50%.
Outside temp. °C
Only in connection with an outside temperature sensor.
Shows the outside temperature.
5.3 Settings