4.1.6 Display last note / delete last note
Selection
Wood Boiler
Wood Boiler
Information
Information
Settings
Operating data
Chimney sweep
Operations counter
Calibrate O
2
*
Aggregates
Aggregate test*
Commissioning
Last error
Last note
Last note
Number --.--
Date YYYY-MM-DD
Delete NO
YES
Delete values
Displays the last note number with date. All notes occurred and the number can be read via data bus.
Call up Selection menu
▲▼ Select Wood Boiler
Confirm selection
Leave menu
▲▼ Select Information
Confirm selection
Leave menu
▲▼ Select Last note
Confirm selection
Leave menu
▲▼ Select Delete
Confirm selection
▲▼ Select YES
Confirm selection
Leave menu
*only displayed in operating status “Boiler OFF“
4.1.7 Delete values
This function is necessary if an already commissioned controller is used on another system
(Technician password required).
Selection
Wood Boiler
Wood Boiler
Information
Information
Settings
Operating data
Chimney sweep
Operations counter
Calibrate O
2
*
Aggregates
Aggregate test*
Commissioning
Last error
Last note
Delete values
Delete values
Boiler set NO
YES
Flue gas max. NO
YES
Heating demand NO
YES
Call up Selection menu
▲▼ Select Wood Boiler
Confirm selection
Leave menu
▲▼ Select Information
Confirm selection
Leave menu
▲▼ Select Delete values
Confirm selection
Leave menu
▲▼ Select value to delete
Confirm selection
▲▼ Select YES
Confirm selection
Leave menu
*only displayed in operating status “Boiler OFF“
Boiler set NO
Possible settings: “NO” / “YES”.
YES: Boiler temperature accumulator of the last 10 burning cycles - return accumulator is deleted.
Return accumulator with Pellet/Oil/Gas boiler on accumulator wood boiler with burner is
deleted.
Flue gas max. NO
Possible settings: “NO” / “YES”.
YES: Maximum value of the flue gas temperature accumulator is deleted. Excessive flue gas
temperatures can occur due to the utilization of unallowable fuel (unauthorized starter fuel, used
oil, plastics …).
Note: Flue gas max. is only a display value it has no control function.