77
ST22: Optional output 3 (WA3): Activation of external pellet/oil/gas boiler
ST22: Optional output 3 (WA3): Activation of electric heating element
ST23: Optional output 4 (WA4): Load-/ Unload valve Y2
3- point-actuator:
ST24: Option output 5 (WA5): Return valve Y1
3-point-actuator:
KL1: N-Load-/ Unload valve Y2
KL2: PE-Load-/ Unload valve Y2
KL3: Y1-Load-/ Unload valve Y2
KL4: Y2- Load-/ Unload valve Y2
Load valve: Phase at Y1 equates: Valve opens: large accumulator circuit
Phase at Y2 equates: Valve closes: small accumulator circuit
Unload valve: Phase at Y1 equates: Valve opens: Consumer-return to the lower accumulator
Phase at Y2 equates: Valve closes: Consumer-return to the upper accumulator
Please be mindful of the correct connection.
N
PE
Y1
PE
Y1
N
Y2
Y2
KL1: N- Return valve Y1
KL2: PE- Return valve Y1
KL3: Y1- Return valve Y1
KL4: Y2- Return valve Y1
Y1 equates: Valve opens: Accumulator circuit
Y2 equates: Valve closes: Boiler circuit
Please be mindful of the correct connection.
N
PE
Y1
N
PE
Y1
Y2
Y2
Please only use an adaptable cable with a 0.75 mm
2
cross
section.
On this output a Load- or an Unload valve can be
connected alternatively.
Please only use an adaptable cable with a 0.75 mm2 cross
section.
Please follow the local safety regulations and be mindful
of the correct connection.
An additional controller to control the switching valve Y3
and the oil/gas boiler must be installed. Please consult
the boiler manufacturer.
KL1: N-Contactor
KL2: PE-Contactor (if required)
KL3: L-Contactor
KL4: WK: Phase input
KL5: Free
KL6: L-Si-Optional output 3
(Fused by 6.3A MT on the plug board via
Si1)
Please be mindful of the correct
connection.
L
PE
N
PE
AK
WK
N
K1
I
max
=5A !!
Bridge!
L-Si
Enabling-Box
KL1: N-contactor
KL2: PE-contactor (if required)
KL3: L-contactor
KL4: WK: Input phase
KL5: Free
KL6: L-Si-Optional output 3
(Fused by 6.3A M at the plug
board via Si1)
PE
AK
WK
N
PE
L
N
L-Si
Please note: The optional output WA3 may be loaded
with a power of Imax=5A. Hence: Always use a contactor
or an auxiliary relay.
Only use an electric immersion heater with an integrated
safety thermostat.
Please follow the local safety regulations and be mindful
of the correct connection.
PE
3x400V~
L1
L2
L3
K1
K1
L3
L2
L1
PE
K1… 3-pol.- contactor
I
max
=5A !!
Bridge!