Heating demand NO
Possible settings: “NO” / “YES”
YES: Heating demand accumulator is deleted.
Important delete function in case of a controller exchange (used controller) – to avoid incorrect
refuel information.
The forecast of the next heating date is based on multiple burning cycles, multiple days and the
first 5 combustions must be started when the refuel signal illuminates.
4.2 Settings
The settings menu contains submenus with similar settings.
4.2.1 Wood settings
*only displayed in operating status “Boiler OFF“
5.01 Type of wood Copper beech
Selection of the type of wood used.
5.02 Moisture medium
Select fuel moisture (“high” / “medium” / “low”).
5.03 Display in %
Only in connection with the option “BSB”.
Display of refuel amount in “%” proportionated to the fuel chamber´s height or in “kg”.
Note: The submenu “Wood settings” enables a different wood setting after the signal “Close door(s)”.
The changed settings operate in the next burning cycle.
5.09 Refuel amount from 50% Setting range 0% - 100%
Only in connection with the option “BSB”.
Display of refuel amount in “%” proportionated to the fuel chamber´s height or in “kg”.
Recommendation: Do not refuel unless the “Refuel” light illuminates.