45
8.2.1 Information
Selection
Pellet/Oil/Gas
Pellet/Oil/Gas
Information
Information
Operation mode
Burner OFF
Settings
Acc. t.-F4 ---.-°C
Chimney sweep
Period ---.-h
Delete period NO
YES
Call up Selection menu
▲▼ Select Pellet/Oil/Gas
Confirm selection
Exit menu
▲▼ Select Information
Confirm selection
Exit menu
▲▼ Select menu item
Confirm selection
▲▼ Change value
Confirm value
Exit menu
Burner OFF
Operating status of the burner.
Possible settings: "ON" / "OFF".
Acc. t.-F4 ---.-°C
Temperature at the accumulator sensor F4.
Period ---.-h
Period counter in hours
Delete period NO
Possible settings: "ON" / "OFF".
The operating hours (as period) for the pellet/oil/gas burner. They can be deleted at any time.
YES: The operating hours (as period) are deleted.
8.2.2 Operation mode
Selection
Pellet/Oil/Gas
Pellet/Oil/Gas
Information
Operation mode
Operation mode
Settings
20.01 Operation mode
Fact.: OFF
ON
Lock time
Anti-freeze
Chimney sweep
Call up Selection menu
▲▼ Select Pellet/Oil/Gas
Confirm selection
Exit menu
▲▼ Select Operation mode
Confirm selection
Exit menu
▲▼ Select menu item
Confirm selection
▲▼ Change value
Confirm value
Exit menu
20.01 Operation mode OFF
Possible settings: "OFF" / "ON" / "Lock time" / "Anti-freeze".
OFF: The pellet/oil/gas boiler is disabled and there is no Anti-freeze available.
ON: The pellet/oil/gas boiler operates in accordance with the settings in 20.03, 20.05, 20.06 and 20.08.
Lock time: The pellet/oil/gas boiler is disabled during the lock time, except if there is an Anti-freeze request.
Anti-freeze: It is set to Anti-freeze.