8.1.1 Operation mode
Selection
Pellet/Oil/Gas
Pellet/Oil/Gas
Operation mode
Operation mode
Settings
20.01 Operation mode
Fact.: OFF
ON
Lock time
Anti-freeze
Call up Selection menu
▲▼ Select Pellet/oil/gas
Confirm selection
Exit menu
▲▼ Select Operation mode
Confirm selection
Exit menu
▲▼ Select menu item
Confirm selection
▲▼ Change value
Confirm value
Exit menu
20.01 Operation mode OFF
Possible settings: "OFF" / "ON" / "Lock time" / "Anti-freeze".
OFF: The pellet/oil/gas boiler is disabled and there is no Anti-freeze available.
ON: The pellet/oil/gas boiler is operating in accordance with the settings in 20.06.
Lock time: The pellet/oil/gas boiler is disabled during the lock time, except if there is an Anti-freeze request.
Anti-freeze: It is set to Anti-freeze.
8.1.2 Settings
Selection
Pellet/Oil/Gas
Pellet/Oil/Gas
Operation mode
Settings
Settings
20.02 Lock time from
Fact.: 00:00
20.02 Lock time to
Fact.: 00:00
20.06 Enabling
Fact.: 42°C
Call up Selection menu
▲▼ Select Pellet/Oil/Gas
Confirm selection
Exit menu
▲▼ Select Settings
Confirm selection
Exit menu
▲▼ Select menu item
Confirm selection
▲▼ Change value
Confirm value
Exit menu
20.02 Lock time from 00:00
20.02 Lock time to 00:00
The period during which the burner is switched off, except for an Anti-freeze request.
In order to delete the lock time, set the same time for from to.
20.06 Enabling 42°C Setting range: 8°C 80°C
The pellet/oil/gas enabling occurs if "Acc. t.-F4" 20.06 Enabling. Then the burner operates in the assigned mode. If
"Acc. t.-F4" rises to 20.06 Enabling + 3K then the enabling is withdrawn.
By pressing the (Recharge) it is switched to accumulator mode.