24
Overt. 10 b/c --.-%
Overtemperature of the last 10 burning cycles.
Use: The user can optimise his refuelling habits quickly.
Delete: If no overtemperature has been detected in the last 10 burning cycles, the value is at 0%.
Calculation: X% of the operating hours of the last 10 burning cycles had over temperature.
Action if display larger than 1%:
Reduce refuel amount, refer to 26.32 Note: System overload.
Boiler t. --------.-h
Total boiler operating hours.
Delete: Requires Manufacturer-password.
Boiler p. --------.-h
Boiler operating hours of one heating period.
Use: Recording of operating hours of one heating period.
Delete: May be deleted by user.
QK total --------.-kWh
Delivered boiler output total = kWh emitted.
Delete: Requires Manufacturer-password.
QK period --------.-kWh
Delivered boiler output of a period.
Use: Collecting kWh of a heating period.
Delete: May be deleted by user.
Service s. in ---.-h
Remaining time until small service request.
Service in ---.-h
Remaining time until service request.
O
2
cal. before ----.-h
In case of daily heating there is no automatic calibration. If operating hours exceed 1500, manual calibration is required
(see chapter 4.4.1).
Contr. --------.-h
Operation hours (online) of the controller.
Delete periods NO
Possible settings: “YES” / “NO”.
Delete YES: Deletes boiler p. (h) and QK-p (kWh); may be deleted by user.
Delete total NO
Possible settings: “YES” / “NO”.
Delete YES: Requires Manufacturer-password.
Deletes boiler t.-p, QK t.-p, Overtemperature total, Overt. 10 burning cycles, service small large,
last error and last note.
Del. Service large NO
Possible settings: “YES” / “NO”.
Delete YES: Requires Technician-password.
Resets the timer of Service.