13.3 Screen Specifications
215
10
13
Chapter 13 Specifications
-1. [SYSTEM] screen
(1) System settings
Setting Choices
CH123 CH4
Wiring 1P2W/1P3W/3P3W2M/3P3W3M/3P4W/3P4W2.5E
AC/DC/OFF
Current sensor and
current range
CT7116 (6 A)/9657-10, 9675: 5 A/500 mA
CT7131 (100 A)/9660, 9695-03: 100 A/50 A
CT7136 (600 A)/9661: 500 A/50 A
CT7044, CT7045, CT7046 (600 A)/CT9667 (500 A): 500 A/50 A
CT7044, CT7045, CT7046 (6 kA)/CT9667 (5 kA): 5000 A/500 A
9669 : 1000 A/100 A
CT7126 (60 A)/9694, 9695-02 : 50 A/5 A
CT7731 (100 A): 100 A/50 A
CT7736 (600 A): 500 A/50 A
CT7742 (2 kA): 5000 A/500 A
Current sensor automatic
detection
Connected sensors that support the HIOKI PL14 connector are automatically detected when selected on
the settings screen.
Phase names R S T/A B C/L1 L2 L3/U V W ―
Zero-adjustment
Zero-adjustment is performed.
Vector area Vector area phase range : ±1° to ±30°
Vector area amplitude range : ±1% to ±30%
Vector area U/I phase difference: -60° to +60°
―
VT ratios
1/60/100/200/300/600/700/1000/2000/2500/5000/User-selectable (0.01 to 9999.99)
CT ratios 1/40/60/80/120/160/200/240/300/400/600/800/1200/User-selectable (0.01 to 9999.99)
Nominal input voltage 100/101/110/120/127/200/202/208/220/230/240/277/347/380/400/415/480/600/User-
selectable (50
V to 780 V, in 1 V increments)
―
Measurement frequency 50 Hz/60 Hz/400 Hz ―
Urms type
* Phase voltage/line voltage ―
PF type* PF/DPF ―
THD type
* THD-F/THD-R ―
Harmonics* U, I, P: All Levels/U, I, P: All content percentage/U, P: Content percentage, I: Level ―
Flicker Pst, Plt/ΔV10
―
Filters
(luminosity curve filters)
230 V lamp/120 V lamp (When Pst or Plt is selected during flicker measurement) ―
*: Detailed description of Urms type, PF type, THD type, and harmonics
Urms type PF type THD type Harmonics
Measured value
(DMM screen)
Selection is applied to RMS voltage (Urms) only
an
d does not affect RMS voltage refreshed
each half-cycle or transient measured values.
Selection is
ap
plied.
Selection is
applied.
Selection is applied.
Measured value display
switching
(DMM screen display only)
Phase voltage/line voltage switched on
DMM screen.
- -
Level/content
percentage switched
on DMM screen.
TIME PLOT and events Selection on main settings screen is applied
to RMS voltage (U
rms) but does not affect
RMS voltage refreshed each half-cycle or
transient events.
Selection on
main settin
gs
screen is applied.
Selection on main
settings screen is
applied.
Selection on main
settings screen is
applied.
Binary data storage
(displayed on computer ap-
plication)
Phase voltage and line voltage
Power factor and
displacement
power factor
THD-F and
THD-R
Level and content
percentage
Other
Valid with 3P3W3M, 3P4W, and 3P4W2.5E
connections. Doe
s not apply to waveform.
DPF values for
ch
annels (ex-
cluding sum val-
ues) for 3P3W2M
and 3
P3W3M
connections are
undefined.