4.3 Changing Recording (Save) Settings
70
Save items
Selects whether to save the average only or all data (average,
maximum, and minimum values) for data that is saved at each
interval. Energy- and demand-related measurement data is saved
regardless of this setting. With the PW3360-21 (which includes
harmonic measurement functionality), you can also set whether to
save harmonic data. Harmonic data cannot be saved in the instru-
ment’s internal memory.
To save harmonic data, set the save destination to [SD CARD].
When the save destination is set to [In
ternal M], ha
rmonic data is
not saved; only recorded measurement data such as voltage, cur-
rent, power, demand, energy, and other data are saved to the
instrument’s
internal memory.
Model PW3360-20 (without harmonic functionality)
Model PW3360-21 (with harmonic functionality)
Selection
AVG only Saves average values only.
ALL data Saves all data (average, maximum, and minimum values).
Selection
AVG only
(no Harmonic)
Saves average values only, excluding harmonic data.
ALL data
(no Harmonic)
Saves all values (average, maximum, and minimum values),
excluding harmonic data.
AVG only
(
w/Harmonic)
Saves average values only, including harmonic data.
ALL data
(w/Harmonic)
Saves all values (average, maximum, and minimum), including
harmonic data.