6.2 Factory Default Settings
131
6
Chapter 6 Changing System Settings
The factory default settings are as follows.
* Items not initialized by System Reset (initialized only by Power-On Reset, p.130).
6.2 Factory Default Settings
Setting Item Default Setting Setting Item Default Setting
Wiring Mode 1 (1P2W x 4) Folder PW3390
Phase correction OFF RS com speed* 38400 bps
Sync source U1, U2, U3, U4 IP address* 192.168.1.1
U range 600 V Subnet mask* 255.255.255.0
U rect RMS Default Gateway* 0.0.0.0
VT rate OFF Language* English
I range Sensor Rating Color Color1
I rect RMS Beep ON
CT rate OFF LCD back light ON
LPF (Input) OFF Start page Wiring
Integ mode RMS Zero suppress OFF
Freq measure U CSV file format CSV
Lowest freq 5 Hz Motor Sync DC 50 ms
Harm sync src U1 LPF
(Motor analysis options)
OFF
THD calc THD-F Freq source f1
-Y convert
OFF
CHA input AnalogDC
Calculation method TYPE1 CHA range 5 V
Efficiency Pin1 to Pin3 P1 CHA scaling 1.0
Pout1 to Pout3 P1 CHA unit N• m
Noise Sampling 100 kS/s Rated torque 1
Points 5000 Freq range fc 60 kHz
Lowest noise 1 kHz Freq range fd 30 kHz
Analysis CH CH1 CHB input Pulses
Window type Hanning CHB range 5 V
Averaging OFF CHB scaling 1.0
ZeroCross filt Strong CHB unit r/min
AutoRange type Narrow Max frequency 5 kHz
Interval 1 min No. of pulses 2
Timer mode OFF Motor poles 4
Timer setting 1 min CHZ OFF
Real time OFF Wave output ON
Sync control Master Freq f.s. 5 kHz
Sync event HOLD Integ f.s. 1/1
Media (Manual saving) CF Card Output range 2 V f.s.
Folder (Manual saving) PW3390 Output items CH1 to
CH16
Urms1
Auto save OFF
Settings for measurement display and recording data are also initialized.