4.3 Integration Value Observation
63
4
Chapter 4 Viewing Measurement Values
Current (I) and active power (P) are integrated on all channels simultaneously. Positive, negative and
total values are displayed.
4.3 Integration Value Observation
4.3.1 Displaying Integration Values
Displaying Integration Contents
Items that can be integrated depend on the selected wiring and integration mode.
See "3.9 Selecting the Wiring Mode" (p. 34), "4.3.2 Setting the Integration Mode" (p. 66)
These items can be selected and displayed on the Selection Display screen.
Press , select a channel [CH] with , then press .
RMS Voltage
RMS Current
Active Power
Power Factor
Integration Time Items
Frequency Measurement
Source Frequency
* Displayed only for DC integration mode
Current Integration Values
Ih1+ CH1 positive current integration value*
Ih1- CH1 negative current integration value*
Ih1 CH1 total current integration value
Example: With 1P2W Wiring mode selected, and DC integration mode
WP1+ CH1 positive active power integration value
WP1- CH1 negative active power integration value
WP1 CH1 total active power integration value
Active Power Integration Values
Integration in progress
Integration stopped
Waiting for integration to start by real-time clock control