EasyManua.ls Logo

Hirschmann RS20

Hirschmann RS20
294 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation Diagnosis
188
9.3
Out-of-band Signaling
Basic Configuration
Release
6.0
07/2010
The device enables you
X to signal changes to the status of the plug-in fan out-of-band (outside the
data flow) via a signal contact (see on page 185 “Monitoring the Device
Status via the Signal Contact“)
X to signal changes to the status of the plug-in fan by sending a trap when
the device status changes
X to detect status changes to the plug-in fan in the Web-based interface on
the system side and
X to query changes to the status of the plug-in fan in the Command Line
Interface.