Code Part Setting options
H3
Operating mode change restriction
00: Operating mode change disabled (hide operating
mode) (factory setting)
01: Operating mode set by the central control unit +
FAN mode
02: Unlimited operation
H4
Ventilation exchange
(total heat exchanger only)
00: Air conditioning only
01: Ventilation only
02: Air conditioning + Ventilation
H5
Central control available after forced stoppage
00: Disabled
01: Enabled
*(1): Some indoor units do not accept setting 02.
*(2): If installed next to a bedside table, use setting 00.
*(3): Applicable to FAN, COOL and DRY modes.
*(4): Applicable to HEAT mode.
*(5): Setting 01 is only available when a remote control is used. Do not use this setting when two controls (main/secondary)
are used.
N O T E
• When several indoor units are connected, the same settings apply to them all.
• To change the settings, wait for over 3 minutes after switching on the power supply.
• Some indoor and outdoor units do not accept certain settings or do not include functions corresponding to the
enabled settings. Check the available settings beforehand.

Table of Contents

Other manuals for Hitachi RPI-4.0FSN4E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi RPI-4.0FSN4E and is the answer not in the manual?

Hitachi RPI-4.0FSN4E Specifications

General IconGeneral
BrandHitachi
ModelRPI-4.0FSN4E
CategoryAir Conditioner
LanguageEnglish

Related product manuals