Installing the Scan Assembly
Setting the Protocol (SW5)
The ACUIX PTZ dome supports the following protocols for communicating with
other devices:
IntelliBus™
•MAXPRO-mode
•VCL
Diamond
Pelco P, Pelco D, Pelco P_AD, Pelco D_AD
Select a protocol that is compatible with the controller or other device that you
want to connect to.
The protocol is set using DIP switch SW5 on the circuit board (see Table 2-3).
The factory default is MAXPRO-mode (a mode of using Diamond protocol which
has special presets for functions beyond pan, tilt, zoom, focus, and preset).
To set the protocol:
•Using Table 2-3 as a reference, position the pins on switch SW5 to
correspond to the protocol that you have selected.
Note Normally, pin 8 should be set to the ON position. Setting the switch to
OFF allows the address, protocol, baud rate, and parity settings to be
changed from the OSD, which is not recommended for most
installations.
Table 2-3 SW5 Protocol Settings
Protocol Name Switch Position
12345678
IntelliBus™ OFF OFF OFF OFF OFF OFF OFF ON
MAXPRO-mode (default)
OFF ON OFF OFF OFF OFF OFF ON
VCL - RS485
ON ON OFF OFF OFF OFF OFF ON
VCL UTC
("Up-the-Coax")
OFF OFF
ON OFF OFF OFF OFF ON
Diamond
ON OFF OFF OFF OFF OFF OFF ON
Pelco P
ON OFF ON OFF OFF OFF OFF ON
Pelco D OFF
ON ON OFF OFF OFF OFF ON
Pelco P_AD
ON OFF ON OFF ON OFF OFF ON
Pelco D_AD OFF
ON ON OFF ON OFF OFF ON