ACUIX™ PTZ High Speed Analog Dome Installation and Configuration Guide
Document 800-05662V1 Rev A 69
04/11
Deleting a Privacy Zone
You can delete a privacy zone that you have programmed.
To delete a privacy zone:
1. Select 6 Function Programming
3 Privacy Zone Options 4 Delete
PrivacyZones.
2. Locate and select the privacy zone you want to delete. If the deletion is
successful, the message
Delete Success appears.
Setting the Security Level of a Privacy Zone
You can set the security level of a privacy zone to high or low.
To set the security level of a privacy zone:
1. Enter preset 75 on the controller.
2. Enter the 4-digit PIN (the default PIN is 1000).
3. Select 4 PrivZone Security Level
High (default) or Low.
If the security level is set to High, you cannot program the privacy zone
at a zoom level of more than 10×. The mask is increased in size after
programming and is temporarily increased in size when zooming in or
out to prevent any portion of the privacy zone from being viewed.
If the security level is set to Low, you can program the privacy zone at
any zoom level. The mask is increased in size after programming (but
less than when the security level is set to High) and is not temporarily
increased in size when zooming in or out.