46
Configuring HDXG Camera Settings
Setting High Sensitivity Mode
High sensitivity mode provides higher sensitivity at the expense of less clearly
defined lines and countours of objects in motion. Enabling high sensitivity mode
selects interlaced scanning, while disabling high sensitivity mode selects
progressive scanning.
To enable/disable high sensitivity mode:
Select 5 Camera Options
3 Video Setup 8 High Sensitivity Mode
ON or OFF (default).
Setting Field Noise Reduction
Field noise reduction (FNR) technology minimizes random noise and
after-images generated by moving subjects, producing clear, sharp images and
improving motion detection performance. Field noise reduction can also reduce
the bandwith and storage volume required if the video is digitized and
compressed. Auto and manual field noise reduction modes are available.
To set the field noise reduction mode:
Select 5 Camera Options
3 Video Setup 9 Field Noise Reduction
1 FNR Mode
Auto (default) or Manual.
•If Auto is selected, you can adjust the level of noise reduction by
selecting 5 Camera Options
3 Video Setup 9 Field Noise
Reduction
2 Auto FNR Slight (default), Weak, Medium, or
Strong.
•If Manual is selected, you can adjust the level of noise reduction by
selecting 5 Camera Options
3 Video Setup 9 Field Noise
Reduction
Manual FNR (O–16), and then selecting a value between
0 (weak) and 16 (strong).
Setting White Balance
If manual white balance is enabled, the red and blue gain settings can be
changed. If manual white balance is disabled, the red and blue gain settings can
be changed but the settings do not take affect until the manual white balance is
enabled again.