Configuring Presets, Tours, Privacy Zones, and Sectors
Configuring Timed Functions
Timed functions allow you to set the dome to perform a preset, preset tour, or
mimic tour at the same time every day for a specified duration. The time
reference is taken from the dome’s Real Time Clock (RTC), which must be set in
the Enhanced Settings menu (see Displaying the Time and Date on page 21).
Note No two timed functions can have the same start time.
To program a timed function:
1. Select 7 Enhanced Settings
7 Timed Functions.
2. In the Function (FUN) column, select one of the following:
P = preset (normal or advanced)
V = preset tour
T = mimic tour
3. In the Number (NUM) column, enter the number of the preset, preset tour,
or mimic tour that you want to set as a timed function. If the number is not
valid, an error message appears.
4. In the Time (TIME) column, enter the time (in 24-hour format) when you
want the dome to begin performing the function. The function will execute
at the same time every day as long as it is enabled.
5. In the Duration (DUR) column, enter how long you want the dome to
perform the function (in hours and minutes). If the duration is set to 0, the
function will execute until the dome is manually controlled or another timed
function is called. At the conclusion of the timed function, the dome
resumes whatever operation it was performing when the timed function was
initiated.
6. In the Enabled (ENA) column, select Y (yes) to enable the timed function, or
select N (no) to disable the timed function.