ACUIX™ PTZ High Speed Analog Dome Installation and Configuration Guide
Document 800-05662V1 Rev A 65
04/11
Configuring Default Functions: Presets and Tours
You can set the dome to go to a preset or run a preset tour or mimic tour after
being idle for a specified length of time.
To program a default function:
1. Select 3 Control Options
5 Set Default Function.
2. In the Function (FUN) column, select one of the following:
P = preset (normal or advanced)
V = preset tour
T = mimic tour
The dome performs the selected function after being idle for the specified
delay time. The function type (and name, if applicable) is displayed on the
screen (for example, a preset might appear as
PS = Entrance Door).
3. In the Number (NUM) column, enter the number of the preset, preset tour,
or mimic tour that you want to set as the default function. If the number is
not valid, an error message appears.
4. In the Delay (DLY) column, enter the time (in minutes and seconds) that
dome must be idle before it performs the default function. The maximum
delay time is 99 minutes and 59 seconds.
5. In the Enabled (ENA) column, select Y (yes) to enable the default function,
or select N (no) to disable the default function.
Note If alarms are present, the dome processes these before performing
the default function. If motion detection is enabled, then the default
function is automatically disabled.