Document 800-05662V1 Rev A 51
04/11
8
Configuring Alarms
This chapter contains the following sections:
• Programming Alarms, page 51
• Setting Alarm Conditions, page 52
• Setting Automatic Acknowledgment Properties, page 52
• Setting Alarm Messages, page 53
• Setting Alarm Overwrite and Overwrite Time, page 53
Programming Alarms
You can program up to four alarm inputs. The input contacts are sampled 16
times per second. When an alarm is activated, the dome performs the function
configured for the alarm (such as go to preset or run mimic tour).
To program an alarm input:
1. Select 3 Control Options
3 Program Alarms 1 Program Alarms.
2. Select the alarm input you want to program (1–4).
3. In the Function (FUN) column, select one of the following:
•P = preset (normal or advanced)
• V = preset tour
• T = mimic tour
• N = night mode
• D = day mode
Note If night mode (N) or day mode (D) is selected, the cursor moves
directly to the Enabled column.