ACUIX™ PTZ High Speed Analog Dome Installation and Configuration Guide
Document 800-05662V1 Rev A 75
04/11
2. Click Next.
The following screen appears:
3. Turn off power to the dome.
4. Remove the bubble from the dome housing.
5. Remove the scan assembly. Push in the two locking tabs on either side of
the scan assembly to release the scan assembly from the dome housing.
6. Click Next.
The following screen appears:
7. Locate DIP switch SW6 on the scan assembly circuit board. Set pin 7 to
ON. Set pin 8 to OFF.
8. Connect one end of an Ethernet crossover cable to the Ethernet port on the
dome housing circuit board.
Note: Ensure that you are using a crossover cable and not a straight-through cable.