On-Screen Setup Menus
2. Select 2 to change the Manual AE Mode. Pressing 2 toggles between the available
settings: Iris, Gain, or Shutter. This setting applies when the controller is set to
manual iris mode.
Video Setup
Select 3 from the Camera Options menu to
access the Video Setup menu. The default
settings are shown to the right.
1. Select 1 to change the Exposure
Level. The default setting is 91; 0 =
dark to 255 = bright. Enter a number
between 0 and 255, then press Enter.
2. Select 2 to change the Maximum AGC
Level. The default setting is 216.
High level (255) = bright picture,
noise in picture.
Low level (0) = dim picture, no noise.
Enter a number between 0 and 255, then press Enter.
3. Select 3 to change the Chroma Level. The default setting is 140.
0 = no color
255 = color is saturated
Enter a number between 0 and 255, then press Enter.
4. Select 4 to toggle the Backlight Compensation ON or OFF. The Backlight
Compensation is only operational when the unit is in Auto Exposure Mode and the
Wide Dynamic Range is off.
Digital Slow Shutter AUTO
Auto AER+3 Mode Settings
NightShot Control AUTO
Auto NightShot Sensitivity LOW
Digital Slow Shutter AUTO
Table 7-13 Auto Exposure Control Mode Settings
Table 7-14 Manual Exposure Modes
Setting Description
Iris (default setting) The iris function is controlled manually and the
camera controls the gain and shutter
automatically.
Gain The gain is manually controlled and the camera
controls the iris and shutter automatically.
Shutter The shutter is controlled manually, and the
camera controls the iris and gain automatically.
VIDEO SETUP
1 Exposure Level ........ _91
2 Max. AGC Level 0-255 .. 216
3 Chroma Level 0-255 .... 140
4 Backlight Comp ........ OFF
5 Auto Slow Shutter Lim ... ¼
6 Wide Dynamic Range .... OFF
7 Interlace Scanning .... OFF