26
Switch Settings
Address Examples
1. To set the camera address to 1, set SW1 = 1, SW2 = 0, SW3 = 0, SW4 = 0
(CAM - 0001).
2. To set the camera address to 125, set SW1 = 5, SW2 = 2, SW3 = 1, SW4 = 0
(CAM - 0125).
Note If the ACUIX is set to address 0000, it will respond to control commands for
any address. That is, if the ACUIX is set to address 0000 and the operator
sends control commands for address 2, the ACUIX addressed 0000 will
perform the commands for address 2. No validation is performed on the
addresses by the ACUIX.
DIP Switch Address Override
DIP Switch SW58 can be set so the ACUIX sets the camera address based on the rotary
switch settings or from memory. SW58 should be kept ON during normal operation so that
the logical address can be changed from the on-screen setup menus.
SW58
OFF Logical address stored in memory overrides the DIP Switch settings.
ON The ACUIX is forced to read from the rotary switches and overrides the logical
address stored in memory.
Factory Defaults
The factory default settings are as follows:
Protocol Honeywell Diamond
Baud rate 9600
Parity No parity
Address Even
Termination None