Operation and Programming with Honeywell VCL Protocol
Program Preset
Up to 160 Presets can be defined. Presets are numbered 0159. Presets 7199 are
reserved for special ACUIX functions and cannot be programmed. Refer to Table 4-2 for
a list of Presets 7199 and their functions.
For example, to program Preset 1 using the HJZTP controller:
1. Move the selected dome to view the desired Preset position, using the joystick,
zoom, focus and iris keys.
2. Press and hold Preset.
3. Press 1.
4. Release Preset. The current position of the dome has now been defined as Preset
1.
Recall Preset
For example, to seek Preset 1 using an HJZTP controller:
1. Press 1.
2. Press Preset. The camera moves at the maximum speed to the previously defined
Preset 1.
The user may also select Presets 14 by single key presses using the keys labeled Preset
1 to 4.
Preset Tours
Caution Continuous Preset Tour operation for extended periods of time
(more than 8 hours) is not recommended. Continuous operation
results in increased zoom lens failure and maintenance expense.
Similarly, avoid setting auto focus to continuous.
Preset Tours function the same for VCL protocol as described in Preset Tours, page 43,
in Chapter 3, Operation and Programming with Honeywell Diamond Protocol.
When using VCL protocol, Preset Tours must be programmed using the on-screen setup
menu. The on-screen setup menus are accessed by sending a Preset 90 command to the
ACUIX.