EasyManua.ls Logo

Honeywell ACUIX - MIMIC Tours; Programming MIMIC Tours

Honeywell ACUIX
148 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ACUIX High Speed Dome User Manual
Document 800-01023 Rev A 71
02/08
Mimic Tours
Mimic Tours operate the same as described for Honeywell Diamond protocol in Mimic
Tours, page 47, in Chapter 3, Operation and Programming with Honeywell Diamond
Protocol.
When the ACUIX is set for VCL protocol the Presets are reserved for programming and
running Mimic Tours.
Programming Mimic Tours
Mimic Tours 13
Presets 83, 84, and 85 have been reserved for programming Mimic Tours 1, 2, and 3.
1. Send a Preset 83 command on the controller to program Mimic Tour 1, send a
Preset 84 command for Mimic Tour 2, send a Preset 85 command for Mimic Tour
3.
2. The ACUIX counts down from 120 to 0. During the 120 second countdown, pan and
tilt the ACUIX and adjust the lens zoom setting as desired. The ACUIX stores the
PTZ commands in the order they were performed during the 120 seconds.
3. Wait for the countdown to reach 0 or send a Preset 86 command to end the
programming mode. The message Program Mimic Tour Complete displays.
The ACUIX stores the PTZ commands in the order you entered them between the
time you started the programming mode until you entered the Preset 86 command.
Mimic Tours 116
Preset 77 has been reserved for programming Mimic Tours 116.
1. Send the ACUIX to Preset 77.
2. Use the joystick tilt up and down function to scroll through the Mimic Tour numbers
until the desired Mimic Tour number displays. Use the joystick pan left and right to
move between the digits, if necessary.
3. Press Iris Open.
4. The ACUIX counts down from 120 to 0. During the 120 second countdown, pan and
tilt the ACUIX and adjust the lens zoom setting as desired. The ACUIX stores the
PTZ commands in the order they were performed during the 120 seconds.
5. Wait for the countdown to reach 0 or send a Preset 86 command to end the
programming mode. The message Mimic Tour Complete displays. The ACUIX
stores the PTZ commands in the order you entered them between the time you
started the programming mode until you entered the Preset 86 command.