ACUIX High Speed Dome User Manual
Document 800-01023 Rev A 47
02/08
Mimic Tours
Sixteen (16) Mimic Tours up to 120 seconds each can be programmed in each ACUIX. A
Mimic Tour stores the manual commands (pan, tilt, and zoom) performed by an operator.
A tour can be recalled by an operator, activated in response to an alarm, or programmed
as the default function when the ACUIX is idle for a specified time.
Program Mimic Tours
Note Mimic Tour programming is only available to a user logged in on the
HEGS5000/5001 controller as the Master user.
Method 1: HEGS5000 LCD (Tours 13)
1. Press Dome Menu.
2. Press + or - until Tour Menu displays on the controller LCD.
3. Press Enter.
4. Press + or - until Program displays on the controller LCD, and press Enter.
5. Enter the Mimic Tour number (13) you desire to program using the numeric keypad
on the controller and press Enter. The controller LCD displays Tour Prgrm Stop.
6. The ACUIX begins to count down from 120 to 0 seconds. Perform the desired pan, tilt,
and zoom commands until the ACUIX times out. The ACUIX saves all commands as
the operator performs them. To end the programming before the ACUIX times out,
press Enter (Tour Prgm Stop) or press Clear/Manual.
A message PROGRAM MIMIC TOUR COMPLETE displays on the monitor.
Method 2: On-Screen Setup Menu
See Mimic Tour (Honeywell Diamond Protocol Only), page 116, in Chapter 7, On-Screen
Setup Menus for more information on setting up Mimic Tours.
Run Mimic Tour
Caution Continuous Mimic Tour operation (no times with zero motion and
autofocus set on pan, tilt, and zoom) is not recommended.
Continuous operation results in increased zoom lens failure and
maintenance expense. Similarly, avoid setting auto focus to
continuous.