Operation and Programming with Honeywell Diamond Protocol
Note The ACUIX supports Preset Tours 1–16 while the HEGS5000 is limited to
running Preset Tours 0–9. Therefore, only Preset Tours 1–9 can be run on an
ACUIX from a HEGS5000 controller.
5. Press Enter.
The dome goes to each programmed Preset at the velocity programmed and for the
dwell time specified and then stops. The ACUIX returns to manual mode and the
letter M displays next to the camera ID.
Run Preset Tour Continuously
To run a Tour continuously means the ACUIX runs the Preset Tour from beginning to end;
then repeats the list until halted by an operator.
Caution Continuous Preset Tour operation for extended periods of time
(more than 8 hours) is not recommended. Continuous operation
results in increased zoom lens failure and maintenance expense.
Similarly, avoid setting auto focus to continuous.
To run a programmed Preset Tour continuously:
1. Enter the Preset Tour (VectorScan) number (19) using the numeric keys.
2. Press VectorScan.
The VectorScan runs continuously until the ACUIX receives another command.
Stop Preset Tour
To stop a Preset Tour, you can:
Manually control the ACUIX by moving the joystick in any direction.
Send the ACUIX to a Preset.
Start another Preset Tour or Mimic Tour.
•Press Flashback.