94
On-Screen Setup Menus
Program Alarms
Select 1 from the Program Alarms menu to
enable/disable alarms and to define the
action to be performed when a contact is in
an alarm state.
1. Position the cursor on the FUN field
using the up, down, left, or right arrow
keys. If using VCL protocol, use the
joystick up, down, left, and right
functions.
2. Select the character (P, V, or T) for the
desired function; P=Preset, V=Preset Tour, or T=Mimic Tour. The function displays
on the screen as PS=, PT=, or MT=, respectively.
3. Enter a number in the NUM field. If the
function is programmed, the title
appears on the screen. For example, if
P (Preset) 1 is entered and it has been
programmed with the title, Entrance
Door, PS = Entrance Door displays
on the screen. If Preset 1 is entered, and
it has not been programmed, PS =
Does Not Exist displays on the
screen. If a Preset is reserved for a
special ACUIX function; PS = PS
Reserved displays.
4. Position the cursor on the ENA field and enter a Y (enabled) or N (disabled).
Note If an alarm is disabled, the ACUIX does not respond to a change of state in
the alarm contact. The ACUIX does not perform the programmed Preset,
Preset Tour, or Mimic Tour. If a Preset, Preset Tour, or Mimic Tour is not
programmed for an alarm, the ACUIX does not respond to a change of state
in the contact.
5. Press Enter when you are finished programming alarms.
See Table 7-1 for field entry.
PROGRAM ALARMS
FUN NUM ENA
1 - --- -
2 - --- -
3 - --- -
4 - --- -
PVT Y-N
Press Enter when done.
PROGRAM ALARMS
FUN NUM ENA
1P1--
2----
3----
4----
PVT Y-N
PS=Entrance Door
Press Enter when done.
Table 7-1 Program Alarm Field Entry
Field Usage
FUN (function) Enter function to perform when alarm occurs (P =
Preset, V = Preset Tour, T = Mimic Tour).
NUM (number) Enter the number of the Preset, Preset Tour, or Mimic
Tour.
ENA (enable) Enter Y to enable or N to disable the alarm.