Operation and Programming with Honeywell VCL Protocol
Run Preset Tour
When the ACUIX is set for VCL protocol there are special Presets reserved for running
Preset Tours.
Preset Tours 13
Preset Tours 1, 2, and 3 can be started using Preset commands 87, 88, and 89,
respectively.
Example: To start Preset Tour 2, send a Preset 88 command.
Preset Tours 116
Preset Tours 116 can be started using Preset command 78.
1. Push the joystick up or down to scroll through the Preset Tour numbers until the
desired Preset Tour number displays. To move between the digit fields move the
joystick left or right.
2. Press Iris Open to select the Preset Tour number displayed.
3. To exit the menu without running a tour, press Iris Close.
When an ACUIX receives a command to run a Preset Tour, the ACUIX goes to the first
Preset programmed in the Preset Tour at maximum velocity (480°/second) for the
programmed dwell time, then goes to the next Preset in the Preset Tour at the
programmed velocity for the specified dwell time, and so on. When a Preset Tour is
running continuously, the ACUIX goes from the last Preset to the first Preset at the
programmed velocity. The amount of time the ACUIX takes to go to each Preset depends
on the programmed velocity and the distance to the next Preset’s pan and tilt coordinates.
The velocity is programmable between 1° to 480° per second.
Stop a Preset Tour
Take manual control (pan, tilt, zoom, or focus) of the ACUIX.
Note The Iris Open/Close commands will not stop a Preset Tour.
Send the ACUIX to a Preset.
Start a Mimic Tour or a different Preset Tour.
Execute any other command addressed to that ACUIX.