77 IFP-300 / IFP-300ECS Manual P/N LS10145-001SK-E:B 12/18/2017
Section 7: IDP, SK, SD and SWIFT™
SLC Device Installation
7.1 List of IDP SLC Devices
The following IDP SLC devices can be used with the control panel. See the appropriate section number in this manual or the device
installation instructions (packaged with the device) for more information.
CAUTION:
To avoid the risk of electrical shock and damage to the unit, power should be OFF at the control panel while installing or servicing
IDP Part Number Model Name/Description Install Sheet PN
IDP-Photo Photoelectric smoke detector
I56-3611-000
IDP-Photo-T Photoelectric smoke detector with thermal (135°F)
IDP-PhotoR Photoelectric replacement smoke detector with remote test capability in DNR I56-3569-000
IDP-Acclimate Multi criteria photoelectric smoke detector with thermal (135°F) I56-3611-000
IDP-Beam Reflected beam smoke detector without test feature
I56-2735-00
IDP-Beam-T Reflected beam smoke detector with test feature
DNR/DNRW Duct smoke detector housing. Non-relay (PhotoR sold separate) I56-3051-00
IDP-Heat Fixed temperature thermal detector (135°F)
I56-3608-00IDP-Heat-ROR Rate-of-rise thermal detector with 135° fixed temperature
IDP-Heat-HT Fixed high temperature thermal detector (190°F)
IDP-Pull-SA Addressable single action pull station I56-3606-00
IDP-Pull-DA Addressable dual action pull station I56-3605-00
IDP-ISO Fault isolator module I56-2729-00
ISO-6 Six fault isolator Module I56-4096-00
IDP-Monitor Monitor module I56-3603-00
IDP-Minimon Mini monitor module I56-3604-00
IDP-Monitor-2 Dual input monitor module I56-3614-00
IDP-Monitor-10 10 input monitor module I56-2731-00
IDP-Relay Addressable relay module I56-3601-00
IDP-Relay-6 Six relay control module I56-2732-00
IDP-RelayMon-2 Multiple Module with 2 Relay Outputs and 2 Monitor Inputs I56-3734-00
IDP-Zone Addressable zone interface module I56-3602-00
IDP-Zone-6 Six zone interface module I56-2733-00
IDP-Control Supervised control module I56-3600-00
IDP-Control-6 Six circuit supervised control module I56-2734-00
IDP-FIRE-CO CO Smoke Detector I56-3946-00
B200S//IV Sounder Base. White or Ivory I56-3387-00
B210LP 6" Flanged Intelligent Detector Base, Low Profile I56-0595-00
B224BI/IV 6" isolator base. White or Ivory I56-0725-00
B224RB/IV 6" relay base. White or Ivory I56-3737-00
B200SR/IV Sounder Base. White or Ivory I56-3392-00
B501 4" mounting base I56-0357-00
B200SR-LF/IV Low Frequency Sounder Base. White or Ivory I56-4152-00
B200S-LF/IV Low Frequency Sounder Base. White or Ivory I56-4151-00
IDP-PHOTO-W/IV
Photoelectric smoke detector. White or Ivory I56-6531-00
IDP-PHOTO-R-W/IV
Photoelectric replacement smoke detector with remote test capability in
DNR. White or Ivory
I56-6532-00
IDP-PHOTO-T-W/IV
Photoelectric smoke detector with thermal (135°F) White or Ivory I56-6534-00
IDP-HEAT-W/IV Fixed temperature thermal detector (135°F). White or Ivory I56-6533-00
IDP-HEAT-ROR-W/IV Rate-of-rise thermal detector with 135° fixed temperature. White or Ivory I56-6533-00
IDP-HEAT-HT-W/IV Fixed high temperature thermal detector (190°F). White or Ivory I56-6533-00
Table 7.1 IDP SLC Devices