EasyManuals Logo

Honeywell Galaxy 2 Series Installation Manual

Honeywell Galaxy 2 Series
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #89 background imageLoading...
Page #89 background image
81
Galaxy 2 Series Installation Manual
4 = Groups
NOTE: The Groups attribute is only available if groups have been enabled on the system (refer to
Option 63 = OPTIONS) and is also dependent upon the programmed output function for
the channel.
The Group attribute allows the channel to be assigned to the groups on the system; a channel can be
assigned to more than one group. The channel will only trigger when an event occurs on one of the
groups assigned to the channel. All channels default to all groups on the system.
On selecting the Groups attribute, the groups that the channel is currently assigned to are displayed.
Press the relevant number keys to toggle the status of the group and press the ent key: if the group
number is displayed on the top line, then the group is assigned to the channel; if a dash (–) appears in
place of the group number, the group has been removed from the channel.
2 = Fixed Reports
1 = Low Bat Ch9
This option enables panel low bat condition signalling. In high speed format, this is transmitted as
a code 8 in channel 9
2 = Invert Open/Close
When enabled, set signals report a code 4 signal on channel 4. If disabled, unset signals report a
code 2 signal on channel 4 (DTMF only).
3 = Send Restores
This option determines when intruder restore signals are transmitted to the monitoring station (fast
format only).
0 = on unset
1 = syst restore
If set to 0, the restore signal is sent, after an alarm condition during a set state, when a user code
is entered to unset the system, or at the end of the confirm time window if an unconfirmed alarm
has occured.
If set to 1, the restore signal is sent after an alarm condition during a set state, when the system is
fully reset.
This option affects high speed format only.
This option defaults to 0 and is required by DD243.
56 - Comms (cont’d)

Table of Contents

Other manuals for Honeywell Galaxy 2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy 2 Series and is the answer not in the manual?

Honeywell Galaxy 2 Series Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy 2 Series
CategorySecurity System
LanguageEnglish

Related product manuals