160 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide
DAT drive is providing poor performance
Action: Be sure the drive is not being used to backup more data than is
recommended for the drive. DAT drives are designed with optimum and
maximum data backup sizes. Refer to the drive documentation to determine the
appropriate data backup size for the drive.
Latest firmware indicates a defective tape, or head clogs occur regularly
Action: Replace the tape.
Other errors are occurring
Action: Replace the drive.
Diskette drive problems
List of problems:
Diskette drive light stays on .......................................................................................................160
A problem has occurred with a diskette transaction...................................................................161
Diskette drive cannot read a diskette..........................................................................................161
Drive is not found.......................................................................................................................161
Non-system disk message is displayed.......................................................................................161
Diskette drive cannot write to a diskette ....................................................................................161
Diskette drive light stays on
Action:
1. Be sure no loose connections (on page 154
) exist.
2. Be sure the diskette is not damaged. Run the diskette utility on the diskette
(CHKDSK on some systems).
3. Be sure the diskette is properly inserted. Remove the diskette and reinsert
correctly into the drive.
4. Be sure the diskette drive is cabled properly. Refer to the server
documentation.