EasyManuals Logo

HP ProLiant ML370 Generation 4 User Manual

HP ProLiant ML370 Generation 4
317 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #228 background imageLoading...
Page #228 background image
228 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide
Audible Beeps: None
Action: None.
Action: Check the System Management Log or OS Event Log for details on the
failure.
Action: Run Insight Diagnostics (" on page 126
Possible Cause: This message indicates Mirrored Memory is enabled and
indicates the amount of memory reserved for this feature.
Action: None.
Advanced Memory Protection mode: RAID memory with Advanced
ECC
...Xxxx MB System memory and xxxx MB memory reserved for RAID.
Audible Beeps: None
Possible Cause: This message indicates RAID Memory is enabled and indicates
the amount of memory reserved for this feature.
An Unexpected Shutdown occurred prior to this power-up
Audible Beeps: None
Possible Cause: The server shut down because of an unexpected event on the
previous boot.
Critical Error Occurred Prior to this Power-Up
Audible Beeps: None
Possible Cause: A catastrophic system error, which caused the server to crash,
has been logged.
HP Insight Diagnostics"
) and
replace failed components as indicated.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant ML370 Generation 4 and is the answer not in the manual?

HP ProLiant ML370 Generation 4 Specifications

General IconGeneral
ProcessorIntel Xeon
Processor SocketSocket 604
ChipsetIntel E7520
Memory Slots8 DIMM slots
RAID SupportRAID 0, 1, 5
Form FactorTower
StorageSATA
Expansion Slots6 PCI-X slots
Power SupplyRedundant power supply optional
Operating System SupportLinux
Drive BaysUp to 8 hot-plug drive bays

Related product manuals