Troubleshooting 281
Event Type: Correctable error threshold exceeded
Action: Continue normal operation, and then replace the memory module during
the next scheduled maintenance to ensure reliable operation.
EISA Expansion Bus Master Timeout (Slot X)...
...EISA Expansion Bus Slave Timeout
Processor Correctable Error Threshold Passed (Slot X, Socket Y)
EISA Expansion Board Error (Slot X)
EISA Expansion Bus Arbitration Error
Event Type: Expansion bus error
Action: Power down the server, and then replace the EISA board.
PCI Bus Error (Slot X, Bus Y, Device Z, Function X)
Event Type: Expansion bus error
Action: Replace the PCI board.
Event Type: Correctable error threshold exceeded
Action: Replace the processor.
Processor Uncorrectable Internal Error (Slot X, Socket Y)
Event Type: Uncorrectable error
Action: Replace the processor.
Real-Time Clock Battery Failing
Event Type: System configuration battery low
Action: Replace the system configuration battery.