Troubleshooting 211
Logical Drive X Status = Recovering (rebuilding data on a replaced drive)
Description: A physical drive in this logical drive has failed and has now been
replaced. The replaced drive is rebuilding from the mirror drive or the parity
data.
Action: No action is required. Normal operations can occur; however,
performance will be less than optimal until after the rebuild process completes.
Logical Drive X Status = Wrong Drive Replaced
Description: A physical drive in this logical drive has failed. The incorrect drive
was replaced.
Action: Replace the drive that was incorrectly replaced. Then, replace the
original drive that failed with a new drive.
CAUTION: Do not run the server setup utility and try to
reconfigure, or data will be lost.
Loose Cable Detected - Logical Drives May Be Marked FAILED Until Corrected
Description: ADU found a loose cable. The Smart Array Controller is unable to
communicate with one or more physical drives. One or more logical drives may
be marked FAILED, and are unusable until the problem is corrected.
Action: Power down the system. Check the cables for a tight connection to the
logical drives. Restart the system. If the error persists, the cables may be
defective.
Mirror Data Miscompare
Description: Data was found at reset initialization in the posted-write memory;
however, the mirror data compare test failed resulting in that data being marked
as invalid. Data loss is possible.
Action: Replace the array accelerator board.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant ML370 Generation 4 and is the answer not in the manual?

HP ProLiant ML370 Generation 4 Specifications

General IconGeneral
ProcessorIntel Xeon
Processor SocketSocket 604
ChipsetIntel E7520
Memory Slots8 DIMM slots
RAID SupportRAID 0, 1, 5
Form FactorTower
StorageSATA
Expansion Slots6 PCI-X slots
Power SupplyRedundant power supply optional
Operating System SupportLinux
Drive BaysUp to 8 hot-plug drive bays