EasyManuals Logo

HP ProLiant ML370 Generation 4 User Manual

HP ProLiant ML370 Generation 4
317 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #229 background imageLoading...
Page #229 background image
Troubleshooting 229
Fan Solution Not Fully Redundant
Audible Beeps:
Possible Cause: The minimum number of required fans are installed, but some
redundant fans are missing or failed.
Action: Install fans or replace failed fans to complete redundancy.
Fan Solution Not Sufficient
Audible Beeps:
Possible Cause: The minimum number of required fans are missing or failed.
Action: Install fans or replace any failed fans.
Fatal DMA Error
Audible Beeps: None
Possible Cause: The DMA controller has experienced a critical error that has
caused an NMI.
Action: Run Insight Diagnostics and replace failed components as indicated.
Fatal Express Port Error
Audible Beeps: None
Possible Cause: A PCI Express port has experienced a fatal error that caused an
NMI.
Action: Run Insight Diagnostics and replace failed PCI Express boards or reseat
loose PCI Express boards.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant ML370 Generation 4 and is the answer not in the manual?

HP ProLiant ML370 Generation 4 Specifications

General IconGeneral
ProcessorIntel Xeon
Processor SocketSocket 604
ChipsetIntel E7520
Memory Slots8 DIMM slots
RAID SupportRAID 0, 1, 5
Form FactorTower
StorageSATA
Expansion Slots6 PCI-X slots
Power SupplyRedundant power supply optional
Operating System SupportLinux
Drive BaysUp to 8 hot-plug drive bays

Related product manuals