Troubleshooting 229
Fan Solution Not Fully Redundant
Audible Beeps:
Possible Cause: The minimum number of required fans are installed, but some
redundant fans are missing or failed.
Action: Install fans or replace failed fans to complete redundancy.
Fan Solution Not Sufficient
Audible Beeps:
Possible Cause: The minimum number of required fans are missing or failed.
Action: Install fans or replace any failed fans.
Fatal DMA Error
Audible Beeps: None
Possible Cause: The DMA controller has experienced a critical error that has
caused an NMI.
Action: Run Insight Diagnostics and replace failed components as indicated.
Fatal Express Port Error
Audible Beeps: None
Possible Cause: A PCI Express port has experienced a fatal error that caused an
NMI.
Action: Run Insight Diagnostics and replace failed PCI Express boards or reseat
loose PCI Express boards.