196 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide
IMPORTANT: This guide provides information for multiple servers.
Some information may not apply to the server you are troubleshooting.
Refer to the server documentation for information on procedures,
hardware options, software tools, and operating systems supported by
the server.
WARNING: To avoid potential problems, ALWAYS read
the warnings and cautionary information in the server
documentation before removing, replacing, reseating, or modifying
system components.
Accelerator Board not Detected
Description: Array controller did not detect a configured array accelerator board.
Action: Install an array accelerator board on an array controller. If an array
accelerator board is installed, check for proper seating on the array controller
board.
Accelerator Error Log
Description: List of the last 32 parity errors on transfers to or from the memory
on the array accelerator board. Displays starting memory address, transfer count,
and operation (read and write).
Action: If many parity errors are listed, you may need to replace the array
accelerator board.
Accelerator Parity Read Errors: X
Description: Number of times that read memory parity errors were detected
during transfers from memory on array accelerator board.
Action: If many parity errors occurred, you may need to replace the array
accelerator board.